A-88 Acutime 2000 Synchronization Kit User Guide
Trimble Standard Interface Protocol
A
Alternatively, the unit will accept a 40 byte input packet containing 5
double-precision floating point values representing the ellipse. The
first 3 are DX, DY, and DZ, which represent an offset in meters from
the ECEF origin for the ellipse. The fourth parameter is the
semi-major axis of the ellipse (called the a-axis) and is also in meters.
The fifth parameter is the eccentricity of the ellipse and is
dimensionless.
"
Caution – The GPS receiver does not perform an integrity check on
the datum values. If unusual inputs are used, the output will be
equally unusual.
0x8E-15
Command Packet 8E-15
Request Current Datum Values
This packet contains only the subpacket ID, 0x15. The response to
this packet is 8F-15.
Table A-72 Command Packet 8E-14
Byte # Type Value Units
0 Superpacket ID 0x14
1-8 DOUBLE DX meters
9-16 DOUBLE DY meters
17-24 DOUBLE DZ meters
25-32 DOUBLE A-axis meters
33-40 DOUBLE Eccentricity
Squared
None